Observation of Breaking Arcs of Ag or Cu Electrical Contact Pairs with a High-Speed Camera
2004
·
Junya Sekikawa
, Takayoshi Kubono
·
IEICE Transactions on Electronics
·
33
Motion of Break Arcs Driven by External Magnetic Field in a DC42 V Resistive Circuit
2008
·
J. SEKIKAWA
, T. KUBONO
·
IEICE Transactions on Electronics
·
22
Arc Length of Break Arcs Magnetically Blown-Out at Arc Extinction in a DC450V/10A Resistive Circuit
2013
·
Hitoshi ONO
, Junya SEKIKAWA
·
IEICE Transactions on Electronics
·
19
Arc Duration of Break Arcs Magnetically Blown-Out in a DC 450V Resistive Circuit
2012
·
Hitoshi ONO
, Junya SEKIKAWA
, et al.
·
IEICE Transactions on Electronics
·
19
Characteristics of Break Arcs Driven by Transverse Magnetic Field in a DC High-Voltage Resistive Circuit
2010
·
Tomohiro ATSUMI
, Junya SEKIKAWA
, et al.
·
IEICE Transactions on Electronics
·
16
Voltage-Current Characteristics of Breaking Arc at Constant Opening Speed in the Air
2004
·
J. Sekikawa
, T. Kubono
·
IEEE Transactions on Components and Packaging Technologies
·
14
Rotational Motion of Break Arcs Driven by Radial Magnetic Field in a DC Resistive Circuit
2009
·
Junya SEKIKAWA
, Takayoshi KUBONO
·
IEICE Transactions on Electronics
·
13
Characteristics of Break Arcs Driven by External Magnetic Field in a DC42V Resistive Circuit
2008
·
Junya Sekikawa
, Takayoshi Kubono
·
IEEE Holm Conference on Electrical Contacts (HOLM)
·
12
An analysis of relationship between contact resistance and fracture of oxide film for connector contacts using finite element method
2014
·
Takaya Kondo
, Hirohito Nakata
, et al.
·
IEEE Holm Conference on Electrical Contacts (HOLM)
·
11
Characteristics of 400 V dc plug and socket-outlet for DC distribution systems
2012
·
Tomonori Iino
, Keiichi Hirose
, et al.
·
International Conference on Renewable Energy Research and Applications (ICRERA)
·
8
Effect of Contact Materials of Ag/SnO2 and Ag/ZnO on Rotational Motion of Break Arcs Driven by Radial Magnetic Field
2010
·
Junya SEKIKAWA
, Takayoshi KUBONO
·
IEICE Transactions on Electronics
·
8
Observation of arc-emitted light between slowly opening electrical contacts using a high-speed camera
2004
·
J. Sekikawa
, T. Kitajima
, et al.
·
IEEE Holm Conference on Electrical Contacts (HOLM)
·
8
Observations of the Eroded Surfaces and the Motion of Arc Spots at Each Breaking Operation of Silver Electrical Contacts
2005
·
J. SEKIKAWA
·
IEICE Transactions on Electronics
·
7
Arc Duration and Rotational Frequency of Break Arcs Driven by Radial Magnet Field in a DC42V Resistive Circuit
2011
·
Naoya TAKESHITA
, Junya SEKIKAWA
, et al.
·
IEICE Transactions on Electronics
·
6
Properties of Short Arc Phenomena on AgCu Electrical Contact Pairs for Automotive Electronics Devices
2007
·
Motoyoshi Murakami
, Hiroshi Ryonai
, et al.
·
IEEE Holm Conference on Electrical Contacts (HOLM)
·
6
Consecutive observations of the relationship between eroded contact surfaces and motion of breaking arc at each breaking operation
2005
·
J. Sekikawa
, T. Kubono
·
IEEE Holm Conference on Electrical Contacts (HOLM)
·
6
An Experimental Equation of V-I Characteristics of Breaking Arc for Ag, Au, Cu and Ni Electrical Contacts
2003
·
Junya Sekikawa
, Takayoshi Kubono
·
IEICE Transactions on Electronics
·
6
Restriction on Motion of Break Arcs Magnetically Blown-Out by Surrounding Walls in a 450VDC/10A Resistive Circuit
2016
·
Keisuke KATO
, Junya SEKIKAWA
·
IEICE Transactions on Electronics
·
5
Rotational Drive of Break Arcs Using a Permanent Magnet Embedded in an Electrical Contact
2009
·
Junya Sekikawa
, Takayoshi Kubono
·
IEEE Holm Conference on Electrical Contacts (HOLM)
·
5
Relationship between Arc Duration and Motion of Arc Spots for Break Arcs of Ag and Ag/ZnO Electrical Contacts
2008
·
J. SEKIKAWA
, T. SUGIO
, et al.
·
IEICE Transactions on Electronics
·
5
Magnetic drive by a small magnet of break arc occurring between electrical contacts in a DC42V/7-21A circuit
2008
·
Junya Sekikawa
, Takayoshi Kubono
·
IEICE Technical Report; IEICE Tech. Rep.
·
5
Spectroscopic Imaging Observation of Break Arcs using a High-speed Camera
2007
·
Junya Sekikawa
, Takayoshi Kubono
·
IEEE Holm Conference on Electrical Contacts (HOLM)
·
5
Temperature Measurements of Breaking Arc between Copper Contacts at Three Constant Speeds (10, 20 and 30 mm/s)
2004
·
Tetsuya Kitajima
, Junya Sekikawa
, et al.
·
IEICE Transactions on Electronics
·
5
Arc Length Just Before Extinction of Break Arcs Magnetically Blown-Out by an Appropriately Placed Permanent Magnet in a 200V-500VDC/10A Resistive Circuit
2020
·
Yuta KANEKO
, Junya SEKIKAWA
·
IEICE Transactions on Electronics
·
4
Arc Duration and Dwell Time of Break Arcs Magnetically Blown-out in Nitrogen or Air in a 450VDC/10A Resistive Circuit
2018
·
Akinori ISHIHARA
, Junya SEKIKAWA
·
IEICE Transactions on Electronics
·
4