Product
Help
Pricing
About
Jobs
Log in
Get started
Author
Add to collection
J.C. Bromley
Observed names:
J. Bromley,
J. C. Bromley
Institution:
Manitoba Hydro
Observed institution:
Manitoba Hydro
OpenAlex ID:
A5079238905
A digital technique for the on-line measurement of dissipation factor and capacitance
2001
·
Pei Wang
, M.R. Raghuveer
, et al.
·
IEEE Transactions on Dielectrics and Electrical Insulation
·
52
Investigation of the flashover of a FRP hot stick while in use for live line work at 500 kV
1999
·
W. McDermid
, J.C. Bromley
, et al.
·
IEEE Transactions on Power Delivery
·
24
Relationship between partial discharge pulse height analysis and subsequent voltage endurance of stator bars and coils
1992
·
W. McDermid
, J.C. Bromley
·
IEEE Transactions on Energy Conversion
·
23
Analysis of converter transformer failures and application of periodic on-line partial discharge measurements
2002
·
W. McDermid
, D.H. Grant
, et al.
·
IEEE Electrical Insulation Conference (EIC)
·
21
Partial discharge screening test for internal voids and delaminations in stator coils and bars
1999
·
W. McDermid
, J.C. Bromley
·
IEEE Transactions on Energy Conversion
·
20
Experience with directional couplers for partial discharge measurements on rotating machines in operation
1999
·
W. McDermid
, J.C. Bromley
·
IEEE Transactions on Energy Conversion
·
18
FRP hot stick flashovers during EHV live line work
2004
·
W. McDermid
, D.R. Swatek
, et al.
·
IEEE Electrical Insulation Conference (EIC)
·
17
Analysis of winding failures in HVDC converter transformers
2003
·
W. McDermid
, A. Glodjo
, et al.
·
IEEE Electrical Insulation Conference (EIC)
·
17
Progress in resolving flashovers of FRP hot sticks during EHV live line work
2005
·
W. McDermid
, D.R. Swatek
, et al.
·
IEEE International Symposium on Electrical Insulation
·
14
Update on partial discharge screening tests for stator bars & coils
2011
·
W. McDermid
, J. C. Bromley
, et al.
·
IEEE Electrical Insulation Conference (EIC)
·
9
The ramp test - its origins, development and application
2010
·
W. McDermid
, J. Bromley
·
IEEE Transactions on Dielectrics and Electrical Insulation
·
9
Response of ramp test to delamination in stator groundwall insulation
2002
·
W. McDermid
, J.C. Bromley
·
IEEE Electrical Insulation Conference (EIC)
·
7
Improvements to partial discharge screening test for stator bars and coils
2002
·
J.C. Bromley
, W. McDermid
·
IEEE Electrical Insulation Conference (EIC)
·
6
High voltage DC ramp testing as a diagnostic of stator insulation condition
2005
·
H.G. Sedding
, B.K. Gupta
, et al.
·
IEEE International Symposium on Electrical Insulation
·
5
Condition assessment of service aged XLPE distribution cable
2002
·
W. McDermid
, J.C. Bromley
·
IEEE Electrical Insulation Conference (EIC)
·
4
Ramp test development and data acquisition
2006
·
W.M. McDermid
, J.C. Bromley
·
IEEE Electrical Insulation Conference (EIC)
·
3
Measurement and location of dielectric anomalies in field aged XLPE cables
2002
·
Y.P. Aksenov
, V. Arsentiev
, et al.
·
IEEE International Symposium on Electrical Insulation
·
3
Response of Capacitive Couplers on a Generating Unit to Various Sources of Partial Discharge
2006
·
W. McDermid
, J.C. Bromley
, et al.
·
IEEE International Symposium on Electrical Insulation
·
2
On-line monitoring of partial discharge in rotating machine windings and auxiliaries including the use of external sensors
2002
·
Y. Aksenov
, M. Golovkov
, et al.
·
IEEE Electrical Insulation Conference (EIC)
·
2
Further experience with the measurement of dielectric anomalies in field aged XLPE cables
2002
·
J.C. Bromley
, W. McDermid
·
IEEE International Symposium on Electrical Insulation
·
2
Recent experience with directional couplers for partial discharge measurements on hydrogen cooled rotating machines in a noisy environment
2002
·
J.C. Bromley
, W. McDermid
·
IEEE Electrical Insulation Conference (EIC)
·
1
Show more works
View as search
Works count:
21
Citation count:
259
H-index:
9
I10-index:
9
Year
Topic
Type