Product
Help
Pricing
About
Jobs
Log in
Get started
Author
Add to collection
Blake R. Smith
Observed names:
B Smith,
B. Smith,
Blake R Smith,
Blake Smith,
Smith, Blake
Institutions:
University of Iowa Hospitals and Clinics,
University of Iowa Health Care
Observed institutions:
University of Iowa,
University of Wisconsin–Madison,
University of Iowa Hospitals and Clinics,
University of Illinois Chicago,
University of Iowa Health Care,
University of Iowa Holden Comprehensive Cancer Center,
University of Pennsylvania
show all 7
ORCID:
0009-0000-0117-2590
Observed ORCID:
0009-0000-0117-2590
OpenAlex ID:
A5109550569
A dynamic collimation system for penumbra reduction in spot‐scanning proton therapy: Proof of concept
2014
·
Daniel E. Hyer
, Patrick M. Hill
, et al.
·
Medical Physics
·
107
PDF
Theoretical Benefits of Dynamic Collimation in Pencil Beam Scanning Proton Therapy for Brain Tumors: Dosimetric and Radiobiological Metrics
2015
·
Alexandra Moignier
, Edgar Gelover
, et al.
·
International Journal of Radiation Oncology*Biology*Physics
·
57
Effects of spot size and spot spacing on lateral penumbra reduction when using a dynamic collimation system for spot scanning proton therapy
2014
·
Daniel E Hyer
, Patrick M Hill
, et al.
·
Physics in Medicine and Biology
·
46
Technical Note: A treatment plan comparison between dynamic collimation and a fixed aperture during spot scanning proton therapy for brain treatment
2016
·
Blake Smith
, Edgar Gelover
, et al.
·
Medical Physics
·
44
Secondary Neutron Dose From a Dynamic Collimation System During Intracranial Pencil Beam Scanning Proton Therapy: A Monte Carlo Investigation
2018
·
Blake R. Smith
, Daniel E. Hyer
, et al.
·
International Journal of Radiation Oncology*Biology*Physics
·
39
Improving Head and Neck Cancer Treatments Using Dynamic Collimation in Spot Scanning Proton Therapy
2016
·
Alexandra Moignier
, Edgar Gelover
, et al.
·
International Journal of Particle Therapy
·
33
Toward improved target conformity for two spot scanning proton therapy delivery systems using dynamic collimation
2016
·
Alexandra Moignier
, Edgar Gelover
, et al.
·
Medical Physics
·
32
Analysis of patient‐specific quality assurance for Elekta Unity adaptive plans using statistical process control methodology
2021
·
Sarah Strand
, Amanda Boczkowski
, et al.
·
Journal of Applied Clinical Medical Physics
·
29
Surrogate gating strategies for the Elekta Unity MR‐Linac gating system
2024
·
Samuel D. Rusu
, Blake R. Smith
, et al.
·
Journal of Applied Clinical Medical Physics
·
25
PDF
Innovations and the Use of Collimators in the Delivery of Pencil Beam Scanning Proton Therapy
2021
·
Daniel E. Hyer
, Laura C. Bennett
, et al.
·
International Journal of Particle Therapy
·
25
A method to select aperture margin in collimated spot scanning proton therapy
2015
·
Dongxu Wang
, Blake R Smith
, et al.
·
Physics in Medicine and Biology
·
25
PDF
Commissioning of a motion management system for a 1.5T Elekta Unity MR‐Linac: A single institution experience
2025
·
Blake R Smith
, Joel St‐Aubin
, et al.
·
Journal of Applied Clinical Medical Physics
·
22
PDF
Development and validation of the Dynamic Collimation Monte Carlo simulation package for pencil beam scanning proton therapy
2021
·
Nicholas P. Nelson
, Wesley S. Culberson
, et al.
·
Medical Physics
·
17
LET response variability of Gafchromic EBT3 film from a Co calibration in clinical proton beam qualities
2019
·
Blake R. Smith
, Mark Pankuch
, et al.
·
Medical Physics
·
16
PDF
Dosimetric delivery validation of dynamically collimated pencil beam scanning proton therapy
2023
·
Nicholas P Nelson
, Wesley S Culberson
, et al.
·
Physics in Medicine and Biology
·
15
PDF
An investigation into the robustness of dynamically collimated proton therapy treatments
2020
·
Blake R. Smith
, Daniel E. Hyer
, et al.
·
Medical Physics
·
15
Ionization Chamber Instrumentation
2021
·
Larry A. DeWerd
, Blake R. Smith
·
CRC Press eBooks
·
14
Technical Note: Optimization of spot and trimmer position during dynamically collimated proton therapy
2019
·
Blake R. Smith
, Daniel E. Hyer
, et al.
·
Medical Physics
·
14
Trimmer sequencing time minimization during dynamically collimated proton therapy using a colony of cooperating agents
2019
·
Blake R Smith
, Daniel E Hyer
, et al.
·
Physics in Medicine and Biology
·
12
On the stability of well‐type ionization chamber source strength calibration coefficients
2020
·
Blake R. Smith
, Larry A. DeWerd
, et al.
·
Medical Physics
·
11
Enhancing Delivery Efficiency on the Magnetic Resonance-Linac: A Comprehensive Evaluation of Prostate Stereotactic Body Radiation Therapy Using Volumetric Modulated Arc Therapy
2024
·
Jeffrey E. Snyder
, Martin F. Fast
, et al.
·
International Journal of Radiation Oncology*Biology*Physics
·
9
Intra-fraction motion of pelvic oligometastases and feasibility of PTV margin reduction using MRI guided adaptive radiotherapy
2023
·
Jeffrey Snyder
, Blake Smith
, et al.
·
Frontiers in Oncology
·
9
PDF
Implementation of a real‐time, ultrasound‐guided prostate HDR brachytherapy program
2021
·
Blake R. Smith
, Sarah A. Strand
, et al.
·
Journal of Applied Clinical Medical Physics
·
9
PDF
Air‐kerma strength determination of an HDR 192Ir source including a geometric sensitivity study of the seven‐distance method
2017
·
Blake R. Smith
, John A. Micka
, et al.
·
Medical Physics
·
9
Clinical experience with adaptive MRI-guided pancreatic SBRT and the use of abdominal compression to reduce treatment volume
2024
·
William S. Ferris
, Benjamin George
, et al.
·
Frontiers in Oncology
·
8
PDF
Show more works
View as search
Works count:
58
Citation count:
719
H-index:
15
I10-index:
20
Year
Topic
Type