Year: 1979
Type: article
Abstract: The Containment Systems Test Facility (CSTF) provides the capability of performing large-scale aerosol behavior experiments at a scale factor of approximately 0.5 in height for a typical reactor containment building. The containment height is 20.3 m, the volume is 850 m/sup 3/, the design pressure is 5 bar, and quantities of sodium up to 1250 kg can be sprayed or spilled for sodium combustion product aerosol sources. Instrumentation is provided for characterization of the aerosol and the containment atmosphere. This paper describes the aerosol sampling techniques and instruments used in the CSTF and discusses their accuracy and reproducibility.
Authors: J.D. McCormack, R.K. Hilliard
Language: English
Subfield: Nuclear Energy and Engineering
Field: Energy
Domain: Physical Sciences
Open Access status: green
Funder: U.S. Department of Energy
Award: G754964215