Abstract: Experimental investigation of concrete-filled steel tube columns with reinforced lattice angle was conducted in this study.The lattice angle was designed to reinforce the concrete-filled steel tube columns by increasing the percentage of steel cross-sectional area.Column specimens having different lengths ranged from 500mm to 3500mm were tested.The behavior and strengths of concrete-filled steel tube columns with lattice angle were investigated.In addition, concrete-filled steel tube columns having same size but without reinforced lattice angle were also tested for comparison.Material properties of the concrete and steel used in the test specimens were measured.A new design method was also proposed for the concrete-filled steel tube columns with reinforced lattice angle.It is shown the design predictions from the proposed method agree with test results well.