A stand-alone test device for Bone Conduction Implant (BCI)

Year: 2014
Type: dissertation
Abstract: Bone conduction hearing is when vibrations in the skull bone stimulate the cochlea and thereby lead to sound perception.Bone conduction hearing aids use this phenomenon to provide an alternative solution for patients with hearing impairment mainly in the outer ear or middle ear.A new Bone Conduction Implant (BCI), which has been designed and developed at Chalmers University of Technology and Sahlgrenska University Hospital, is an alternative to the percutaneous Bone Anchored Hearing Aid (BAHA) that is attached to the skull bone via a skin penetrating titanium screw.Although BAHA has been successful for three decades, the skin penetration requires a life-long daily care and may lead to complications such as skin infections or loss of implant.In the BCI, no skin penetration is required and the skin is kept intact.The BCI consists of an external sound processor with a transmitter coil to transmit the sound via an inductive link to a receiving coil in the implanted unit.Then, the sound signal is converted to the mechanical vibrations by a Balanced Electromagnetic Separation Transducer (BEST).This project aims to develop methods for functionality testing of the BCI in situ.It is very important to detect a possible malfunctioning implant during surgery, and also to have methods to follow the implant performance over time and to make a quick performance verification test in situ.The first phase of this project, which has been reported by Shirinkar and Ghoncheh (2013), was dealing with a non-invasive method using nasal sound pressure (NSP) to verify the functionality of BCI during surgery before the surgical incision is closed.The results clearly implied that the NSP method is suitable for the test and verification of the implanted part of the BCI.This was confirmed in the first surgery.The NSP method is also used in follow-up of patients to verify the functionality of the implanted unit of the BCI.This report deals with the second phase of the project with the aim to develop a more simple battery operated stand-alone test device.Initially, different possible solutions for BCI verification were investigated based on an electrical signal driving the transmitter unit and by measuring the frequency response by a sound probe in ear canal or nasal cavities or acoustically emitting from the outer skin surface over the implant.Among different options to generate a proper signal for stimulation, it was decided to use pure tones because it produces familiar signals to human ear.It was found that the transmitted electrical signal to the implant can be heard in the surrounding environment as an aerial sound from the transducer vibrations that are emitting through the skin.As this is a simple and easy-to-do test it was decided to implement this in the battery operated BCI audio processor.Tones with different frequencies were generated using the pre-configured DSP (R3910 from ON semiconductor).To evaluate the efficiency of the test device, two listening tests were performed with different signals.The conclusion is that the battery operated test device developed can be used by clinicians and doctors to verify implant performance both during surgery and post implant follow ups.
Language: English
Open Access status: green
OpenAlex ID: W118935885
Cites: 16
Cited by:
Related to: 10