Abstract: The major influence of the wind is observed in infiltration, the random leakage of outside air into the conditioned volume of a residential-scale building. A model that predicts infiltration from both wind and temperature influence to within 20% will be presented. A comparison is made between the predicted and the measured infiltration from a full-scale test structure, revealing an average discrepancy of less than 10 m/sup 3//hr (out of an average of approximately 150 m/sup 3//hr). Direct measurements of the wind velocity and pressure coefficients induced by the wind on the full-scale test structure are also presented.