Work

Capabilities of the High Voltage Stress Test System at the Outdoor Test Facility

Year: 2005
Type: article
Abstract: We illustrate the capabilities of the High Voltage Stress Test (HVST) which operates continuously in the array field east of the Outdoor Test Facility at the National Renewable Energy Laboratory. Because we know that photovoltaic (PV) modules generating electrical power in both residential and utility-scale array installations will develop high-voltage biases approaching 600 VDC and 1,000 VDC, respectively, we expect such high voltages will result in current leakage between cells and ground, typically through the frames or mounts. We know that inevitably such leakage currents are capable of producing electrochemical corrosion that adversely impacts long-term module performance. With the HVST, we stress or operate PV modules under high-voltage bias, to characterize their leakage currents under all prevailing ambient conditions and assess performance changes emanating from high-voltage stress. We perform this test both on single modules and an active array.
Authors: del Cueto, J. A., Trudell, D., Sekulic, W.
Language: English
Open Access status: green
Award: G43505591
OpenAlex ID: W129357562
FWCI: 0.269
Cites: 2
Cited by: 9
Related to: 10