Navigation multi-bifurcations de corps ferromagnétiques avec un scanner d’imagerie par résonance magnétique

Year: 2015
Type: dissertation
Abstract: The number of new cases of Hepatocellular Carcinoma (HCC), one type of liver cancer, is on the rise. HCC is the second leading cause of cancer death worldwide, due to extremely low survival rate. Prognosis is very poor: the overall 5-year relative survival rate is 12% in the USA and 20% in Canada. The number of available treatments for patients diagnosed at distant stages of the disease is low. A possible treatment is the transarterial chemoembolization (TACE). TACE consists in a combined injection of embolic material and chemotherapeutic drugs. The benefit of TACE is two-fold: embolisation of tumor feeding arteries and local release of anti-cancer drugs directly to the tumoral cells. Unfortunately, without any control, these vectors may reach and kill surrounding healthy liver cells. To increase patient care, we propose to use the Magnetic Resonance Imaging scanner (MRI) as an actuator to navigate therapeutic microparticules into the bloodstream toward liver lesions. Potential outcomes for the patient are, among others, a reduction of side effects and a less invasive intervention. Not restricted to liver, Magnetic Resonance Navigation (MRN) shows promises to drastically change some medical procedures and to increase cancer patient care and management. This thesis decribes strategies to achieve MRN along multiple consecutive channels. In this objective, several experiments have been conducted. Firstly, we showed that a 1-mm bead can be navigated along four consecutives microfluidic channels using an imaging coil. A microfluidic phantom has been designed to obtain eight paths with three bifurcations (two possible choices at every junction). Using magnetic gradient amplitudes lower than 40 mT/m, which are equivalent to clinical MR scanners performance, we successfully steered a bead in all the eight paths. The velocity of the bead reached 14 cm/s. Following these experiments, we worked on potential issues regarding heat rise in the coil. Indeed, imaging coils heats up very quickly when used for MRN and therefore require some time to cool. Without any temperature management strategies, the navigation time over cooling time ratio can be low and thus the procedure duration may be longer. We therefore suggested using the cooling deadtime to apply imaging sequences and acquire information about injected dose or to re-assess navigation parameters. Experimentally, since no temperature rise was measured during the imaging sequences, there is no performance loss. From these observations, more characterisation tests were conducted on the imaging coil to find the most critical parameters regarding the heat rate. We measured an average time of two minutes before the coil reaches its critical temperature. In the worst-case scenario, where at least two gradients are applied simultaneously, less than one minute of propulsion at maximum power is available. From these results, a temperature model has been derived to predict heat rise according to the characteristics of the propulsion sequence. These equations will be integrated within a broad MRN model. Lastly, the inherent design of MRI only allows the application of a single force vector upon all magnetic bodies within a volume. It is therefore impossible to steer a continuous stream of particles along multiple consecutive vessels. One requirement for multiple-bifurcation navigation is therefore to create a discrete injection of particles (bolus) such that only one bolus is navigated at a time. Furthermore, a second requirement for multiple-bifurcation navigation is the synchronisation of the release of the bolus from the catheter with the start of the propulsion sequence.
Language: French
Open Access status: green
OpenAlex ID: W1431765700
Cites: 199
Cited by: 1
Related to: 10