Year: 1990
Type: article
Abstract: This paper describes the thermal and light output performance variations for some representative compact fluorescent fixtures. Experimental data is presented showing the changes in relative light output and temperature for both screw-in and dedicated compact fluorescent fixtures systems. Initial experimental data shows that substantial losses in fixture efficiency can occur in compact fluorescent fixtures due to elevated temperature conditions inside the lamp compartment. These elevated temperatures affect the minimum lamp wall temperature of the compact fluorescent lamp and the corresponding light output and efficacy characteristics of the lamp ballast system. This paper also presents experimental data on various methods to reduce compartment and lamp wall temperatures in order to increase fixture efficiency.
Language: English
Subfield: Building and Construction
Field: Engineering
Domain: Physical Sciences
Open Access status: green
Funder: U.S. Department of Energy
Awards: G1398330795, G1643223109, G193590374