Utjecaj atrioventrikulskog intervala na interventrikulsku disinkroniju i udarni volumen u bolesnika s totalnim AV blokom i implantiranim DDD elektrostimulatorom srca
Year: 2010
Type: dissertation
Abstract: Although right ventricle pacing reduced mortalitiy and has saved lives since it's been in use, still, asynchronous electircal activity results in significant haemodynamical and electrophysiologic changes in the heart. Asynchronous contraction causes shortening in the ejection time and reduces duration of pressure elevation and reduction in the left ventricle and also increases the duration of isometric contraction and relaxation. Those are the reasons for negative haemodynamic effect of right ventricle apex stimulation. Asynchornous electrical activation leads to asynchoronous contraction which then reduces the stroke volume. Also asynchronous contraction leads to asymmetric hypertrophy. All of these cause ventricular dilatation which then leads to increased wall tension. This is the short description of processes that lead to heart failure in almost 25% of patients who are implanted with cardiac pacemaker with right ventricle apex stimulation. The aim of our study was to evaluate individual AV interval optimization as a programmable parameter that could reduce interventricular dyssynchrony and influence on diastolic and systolic function of the left ventricle. We included patients with structurally normal heart who were implanted dual chamber pacemaker for complete AV block in University Hospital ''Sestre milosrdnice'' in Zagreb, Croatia. In the acute phase of optimization, significant number of patients (71,7%) reduced interventricular dyssynchrony and also had higher stroke volume (81,7%). Total of 63,3% both reduced interventricular dyssynchrony while also raising the stroke volume. Further analysis showed no significant difference between patients in acute phase. Only 15% of patients reduced interventricular dyssynchrony for more than 10%, while only 11,6% patients had rise in stroke volume for more than 10% as a response on acute optimisation of AV interval. Patients who responded better in the acute phase were significantly younger (p=0,046) and had higher oxygen consumption values (p=0,039). Patients were divided in two groups, one with nominal and other with optimal AV interval. Patients were followed for 6 months. Patients with optimal AV were thinner (p=0,008), had higher values of ejection fraction (p=0,001), higher stroke volumes (p<0,001), higher level of oxygen consumption, meaning better functional capacity (p=0,022), smaller enddiastolic diameter (p=0,122) and lower values of ANP (p=0,022) after 6 months of follow up. Interventricular dyssynchrony (p=0,084), end-systolic diameter (p=0,122) and BNP values (0,074) were not significantly different between the two groups after 6 months. Patients with nominal AV interval were more obese (p<0,018), had lower values of ejection fraction (p<0,001), had larger enddiastolic diameter (p<0,001), larger end-systolic diameter (p<0,001), had reduced functional capacity (p<0,001). Also, they had higher values of ANP (p=0,001) and BNP (p<0,001) after six months of follow up. At the end of the follow up, dyssynchrony (p=0,495) and stroke volume (p=0,156) were not significantly different than at the beginning. After six months, patients who were left in the optimal AV interval had significantly lower values of BMI (p<0,001), had higher values of EF (p<0,001), smaller end systolic diameter (p=0,037). Also, they had better functional capacity (p<0,001) and lower values of ANP (p=0,003). Predictors for significantly higher stroke volume (more than 10%) after 6 mmonths were optimal AV interval (p=0,010; OR 61,36), higher oxygen consumption (p=0,035; OR 1,19). Significant predictors for higher stroke volume and smaller degree of dyssynchrony were younger age (p=0,026; OR 0,91), smaller end diastolic diameter (p=0,011; OR 0,74). Using individual optimization of the AV interval one could directly increase the stroke volume and systolic function of the left ventricle with positive haemodynamic effects. We did not prove that individual optimization of AV interval could lead to reduction of itnerventricular dyssynchrony. However, the difference in dyssynchrony between the two groups was present but it didn't reach statistical significance. Therefore, future studies with larger number of patients are needed to evaluate our hypothesis.
Author: Manola, Šime
Institution: University of Zagreb
Language: English
Subfield: Cardiology and Cardiovascular Medicine
Field: Medicine
Domain: Health Sciences
Keywords: atrioventricular interval, interventricular dyssynchrony, dual-chamber pacemaker, DDD pacing, right ventricular apical pacing, stroke volume, left ventricular ejection fraction, heart failure, oxygen consumption, functional capacity, left ventricular function, right ventricular function, atrioventricular block, ventricular hypertrophy
Open Access status: green
OpenAlex ID: W145977125