Year: 1990
Type: conference-paper
Abstract: The Advanced Photon Source (APS) to be constructed at Argonne National Laboratory (ANL) utilizes magnetic devices which generate x-ray beams with very intense heat flux levels. The flux levels encountered can be one or two orders of magnitude higher than those commonly found in nuclear reactors or fusion devices. The beam line elements and optics on such beams pose significant challenge to the researchers and designers to keep them cooled at acceptable levels of surface temperature and/or temperature gradients. Therefore, methods and techniques achieving heat removal enhancement are constantly sought. One such technique suggested and considered is the use of conductive metal wool filled tubes where the filter is brazed to the tube walls. A comparative investigation of the conventionally achievable heat transfer coefficient h'' with water and the wall conductance of a heavy wall copper tube reveals that major resistance is on the coolant side. Therefore, there exists a significant opportunity to improve heat transfer in the tubes by enhancement of the coolant side. To this end a variety of copper wool filled tubes as well as a commercially available enhanced copper tube were subjected to laboratory tests with water and conventional heating to assess the resulting heat transfer improvement. Design improvements using enhanced cooling are discussed in terms of structural weight, controls, grazing angles, the operational reliability. 9 refs., 11 figs., 5 tabs.
Language: English
Subfield: Mechanical Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W1482229299