Work

Roof Apertures in Office Buildings

Year: 1983
Type: article
Abstract: An investigation has been made of potential 1 ighting electricity reductions and associated thermal impacts of replacing electric light with sunlight admitted through rooftop glazing on a single-story, prototypical offi ce buil di ng.Experimental scal e model s have been used to determi ne the fraction of the solar radi ation enteri ng the aperture which reaches the work pl ane as useful ill umi nation.Thi s i nformati on is used ina developmeDtal version of the buil di ng energy analysi s computer program BLAST-3.0:!> to predict reductions in lighting electricity and the impacts on energy consumption for heating and cooling the building.The results indicate that a large fraction of the electricity consumed for lighting a single-story office building can be displaced using modest amounts of glazing in the roof.Also, both heating and cooling energy consumption reductions are possible from a daylighting system, but they are substantially smaller than the potential lighting electricity reductions.The design implications of the results are discussed and future directions for the work are outlined. I NTRODUCTI ONProviding illumination in buildings using sunlight as a substitute for electric light is attractive for several reasons: .
Language: English
Open Access status: green
OpenAlex ID: W14839178
FWCI: 7.725
Cites:
Cited by: 3
Related to: 10