Work

An Improved Analytic Model for Microdosimeter Response

Year: 2001
Type: article
Abstract: An analytic model used to predict energy deposition fluctuations in a microvolume by ions through direct events is improved to include indirect delta ray events. The new model can now account for the increase in flux at low lineal energy when the ions are of very high energy. Good agreement is obtained between the calculated results and available data for laboratory ion beams. Comparison of GCR (galactic cosmic ray) flux between Shuttle TEPC (tissue equivalent proportional counter) flight data and current calculations draws a different assessment of developmental work required for the GCR transport code (HZETRN) than previously concluded.
Authors: L Shinn Judy, Walter John, A Xapsos Michael
Language: English
Subfield: Radiation
Open Access status: green
OpenAlex ID: W1487970514
FWCI:
Cites: 24
Cited by:
Related to: 10