Work

An Investigation of Mist/Air Film Cooling with Application to Gas Turbine Airfoils

Year: 2012
Type: article
Abstract: Film cooling is a cooling technique widely used in high-performance gas turbines to protect turbine airfoils from being damaged by hot flue gases. Film injection holes are placed in the body of the airfoil to allow coolant to pass from the internal cavity to the external surface. The ejection of coolant gas results in a layer or “film” of coolant gas flowing along the external surface of the airfoil. In this study, a new cooling scheme, mist/air film cooling is proposed and investigated through experiments. Small amount of tiny water droplets with an average diameter about 7 μm (mist) is injected into the cooling air to enhance the cooling performance. A wind tunnel system and test facilities were build. A Phase Doppler Particle Analyzer (PDPA) system is employed to measure droplet size, velocity and turbulence. Infrared camera and thermocouples are both used for temperature measurements. Mist film cooling performance is evaluated and compared against air-only film cooling in terms of adiabatic film cooling effectiveness and film coverage. Experimental results show that for blowing ratio M=0.6, net enhancement in adiabatic cooling effectiveness can reach 190% locally and 128% overall along the centerline. The general pattern of adiabatic cooling effectiveness distribution of the mist case is similar to that of the air-only case with the peak at about the same location. The concept of Film Decay Length (FDL) is proposed to quantitatively evaluate how well the coolant film covers the blade surface. Application of mist in the M=0.6 condition is apparently superior to the M=1.0 and 1.4 cases due to the higher overall cooling enhancement, the much longer FDL, and wider and longer film cooling coverage area. Based on droplet measurements through PDPA, a profile describing how the airmist coolant jet flow spreads and eventually blends into the hot main flow is proposed. A sketch based on the proposed profile is provided. This profile is found to be well supported by the measurement results of Turbulent Reynolds Stress. The location where a higher magnitude of Turbulent Reynolds Stress exists, which indicates higher strength of turbulent mixing effect, is found to be in the close neighborhood of the edge of the coolant film envelope. Also the separation between the mist droplets layer and the coolant air film is identified through the measurements. In other words, large droplets penetrate through the air coolant film layer and travel further over into the main flow. Based on the proposed air-mist film profile, the heat transfer results are reexamined. It is found that the location of optimum cooling effect is coincident with the starting point where the air-mist coolant starts to bend towards the surface. Thus the data suggests that the “bending back” film pattern is critical in keeping the mist droplets close to the surface which improves the cooling effectiveness for mist cooling.
Author: Lei Zhao
Language: English
Open Access status: green
OpenAlex ID: W1496915216
FWCI: 1.685
Cites: 62
Cited by: 5
Related to: 9