Year: 1994
Type: conference-paper
Abstract: As CFC refrigerants are now being phased out as quickly as possible and as the full effects of replacement refrigerants on the environment may still be unknown, it would be ideal to find a refrigerant that was environmentally benign beyond question.Air is such a refrigerant.The characteristics of a small commercial refrigerator that uses R134a refrigerant are used as a basis for a preliminary design of an air cycle refrigerator that would have similar characteristics. F"'ISC h h' k m coefficient of performance specific heat at constant pressure isentropic enthalpy factor isentropic work ratio specific enthalpy NOMENCLATUR E specific enthalpy after an ideal isentropic process specific heat ratio, c P j cv mass flow rate pressure specific cooling effect cooling effect temperature after an ideal isentropic process temperature net work input = compressor work -expander work isentropic efficiency of compressor isentropic efficiency of expander
Authors: Jim McGovern, B. Duignan
Institution: Purdue University West Lafayette
Language: English
Subfield: Mechanical Engineering
Field: Engineering
Domain: Physical Sciences