Developing Method of Differential Pulse Polarographic for Analysis of Chloramphenicol Residue in Milk

Year: 2010
Type: article
Abstract: A differential pulse polarographic method for a quantitative analysis of chloramphenicol residue in milk had been developed. Result showed that the method using dropping mercury electrode as working electrode, Ag/AgCl electrode as reference electrode, and platinum electrode as auxiliary electrode with an acetic buffer solution of pH 4.7 as supporting electrolyte had a recovery for chloramphenicol of (96.88 ± 3.17)% with a detection limit of 0,027 µg/mL, a quantitation limit of 0,089 µg/mL, and a determination limit of 0,010 µg/mL. Keywords: differential pulse polarography, residue, chloramphenicol, milk
Language: English
Field: Chemistry
Open Access status: gold
Estimated APC paid: $300
OpenAlex ID: W1514805132
FWCI:
Cites: 9
Cited by: