Imprinting Zeolite-modified Glassy Carbon as a Voltammetric Sensor for Uric Acid
Year: 2013
Type: article
Abstract: Development of the uric acid sensor through coating of glassy carbon (GC) electrode with imprinting zeolite (IZ) was carried out. Zeolite was synthesized by mixing TEOS, TBOT, TPAOH, and water followed by hydrothermal process. Zeolite was molded together with uric acid to produce IZ. The deposition potential of IZ and uric acid to the GC surface was -0.6 V during 150 sec with addition of KNO3 0.02 M as supporting electrolyte. The method gives linearity of 0.9834 (concentration 5.6x10-9M - 2.8x10-8 M), precision 1.89 - 7.65%, sensitivity 0.33 µA/nM/cm2, limit of detection 5.9x10-9 M, and accuracy 96.26 ± 0.55% (n = 5). The developed sensor showed a high selectivity toward uric acid. The presence of ascorbic acid, creatine, and creatinine with an equal concentration with uric acid did not interfere on the uric acid analysis.
Source: Indonesian Journal of Chemistry
DOI: 10.22146/ijc.21292
Institution: Universitas Airlangga
Language: English
Subfield: Analytical Chemistry
Field: Chemistry
Domain: Physical Sciences
Open Access status: gold
Estimated APC paid: $300
OpenAlex ID: W1530068642