Abstract: The particle size that most greatly penetrates a filter is a function of filter media construction, aerosol density, and air velocity. In this paper the published results of several experiments are compared with a modern filtration theory that predicts single-fiber efficiency and the particle size of maximum penetration. For high-efficiency particulate air (HEPA) filters used under design conditions this size is calculated to be 0.21 ..mu..m diam. This is in good agreement with the experimental data. The penetration at 0.21 ..mu..m is calculated to be seven times greater than at the 0.3 ..mu..m used for testing HEPA filters. Several mechanisms by which filters may have a lower efficiency in use than when tested are discussed.