Work

A Novel Dental Implant Technology for Early Bone Formation by Electrical Stimulation

Year: 2006
Type: conference-paper
Abstract: We developed a novel dental implant technology for early bone formation using electrical µ-current stimulator integrated in healing abutment of implant. Electrical stimulation makes a early bone formation possible for early loading of implants. In order to implement small sized stimulation system, we needed a small chip that could be operated on a tiny battery. Thus, we designed a current stimulator chip using 0.35µm fabrication process of SAMSUNG semiconductor through the 41st IDEC MPW program. The chip is composed of 5 parts, which is a clock generation block, duration setting block, pulse rate setting block, amplitude setting block and biphasic pulse control block. In our system, stimulation parameters are fixed with 120µs of duration, 100Hz of pulse rate and 20µA/㎠ of amplitude and power is delivered by a serial connected silver oxide battery(SR421SW, Sony) of which dimension is 1.65mm of thickness and 4.8mm of diameter. The chip consumed 142µW power and lasted 7 days in an implanted site. The fabricated chip is wire bonded with printed circuit board (PCB) and packaged in a healing abutment made with Poly-carbonate insulating materials. Reference electrode(screw) and channel electrode(cap) made with the material of pure titanium are soldered with the PCB using a fine pt wire. In order to give a tolerance against the external shock, the fast setting adhesive epoxy was injected inside the healing abutment with integrated system. We implanted the current stimulator system into the 10 dogs(Beagle). After pulling out premolar of maxillary and mandibular, wounded sites were stabilized for 45 days. Then, the system was implanted in mandibular first premolar with the control. Electrical stimulation was applied for 1 weeks and the test group was sacrificed at 2 weeks after stimulation. Histological specimens with H&E and Masson Trichrome staining were made and histomorphometrically analysed with image analyser. A new bone formation was observed around implants in the experimental group. The area of a new bone was increased from 13.77% to 43.93% compared to that of control. These results suggest that our newly developed system is effective in the early bone formation around the surface of implant. It can be a useful method in clinical application for the early loading of implant.
Language: English
Subfield: Oral Surgery
Field: Dentistry
Open Access status: green
OpenAlex ID: W153774063
FWCI:
Cites:
Cited by:
Related to: 8