An investigation of adjustable microgravity workstation anthropometrics through analyses of neutral body posture and lower leg muscular fatigue characteristics
Year: 1989
Type: dissertation
Abstract: This research investigates the use of adjustable worksurfaces for microgravity.The tasks being performed in space are becoming longer duration, stationary tasks, such as the scientific monitoring typical of Spacelab flights of the Space Shuttle.It is thus becoming more critical to have the task implements proximal to each individual's zero-g neutral posture hand positions.Performing a long duration task in a posture far from this ideal requires fatiguing isometric contractions, and indeed, a number of astronauts do complain of marked fatigue of the anterior lower leg muscles when performing tasks in foot-loop restraints.The neutral body posture is analyzed by a unique approach in this study.Anthropometric measures were obtained from a group of experimental subjects, and, in combination with the Skylab data of the zero-g posture, are used to predict the theoretical positions of each of the major joints of the body, relative to the ankle, for footrestrained individuals in weightlessness.These analyses support a hypothesis that, the variability of hand positions in zero-g neutral posture is greater than that of the one-g overall heights, thereby suggesting the need for adjustability in microgravity workstation design.In addition, analysis of the distances of the major bodily joints from the mean values for those joints, suggests a means for understanding the degree of fatigue induced in the various skeletal muscle sets, during tasks requiring other than the neutral posture, and provide a basis for a focus on the anterior lower leg muscles for further study.Finally, by utilizing photographic recording of posture, this study has demonstrated that the neutral posture of underwater buoyancy is a highly similar analogue to that of microgravity, and is thus an effective means of simulating long duration task conditions of orbital spaceflight, for research.This technique was utilized in a comparison of the fatigue levels at adjustable and fixed worksurfaces, for subjects performing keyboard entry tasks underwater, by the recording of electromyographic (EMG) signals from the Tibialis anterior muscle.The median frequencies of EMGs have been shown by past research to decline with fatigue, and such declines were indeed produced.Although inconclusive, the results are suggestive for future research.
Author: Theodore Pashley McDade
Institution: Massachusetts Institute of Technology
Language: English
Subfield: Aerospace Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W1539154928