Work

Rheological Characteristics of the Vocal Cord : Measurement of the Damping Ratio

Year: 1979
Type: article
Abstract: The damping ratio of the vocal cord was measured in human larynges extirpated at autopsy or at surgery. The damped oscillation was produced by releasing the vocal cord from a displaced position. The damping ratio of the vocal cord in the autopsy case was 0.237 and in the surgical cases 0.320 and 0.344. Damped oscillation with a given damping ratio was simulated by use of computer.
Language: English
Open Access status: green
OpenAlex ID: W155963439
FWCI:
Cites: 1
Cited by: 1