Work

Residual Stress Measurement of Micro Gold Electroplated Structure

Year: 2000
Type: article
Abstract: In this paper, a simple method to measure the residual stress in microstructure is presented. In order to find the residual stress in micro-machined beam, the first natural frequency of the beam that has the residual stress inside is analyzed using Rayleigh's energy method. Micro gold electroplated structure is fabricated by surface micro-machining process including electroplating. The made structure is an approximate shape of clamped-clamped beam and its 1st natural frequency is measured by resonance method. For the better estimation of the residual stress, an equivalent length of micro-fabricated beam to ideal beam is calculated by FEM. The residual stress was estimated from the equivalent length and the measured natural frequency. It was found that a tensile stress was residue in the micro beam structure.
Language: English
Open Access status: diamond
OpenAlex ID: W1568423592
FWCI:
Cites:
Cited by:
Related to: 10