Year: 1990
Type: conference-paper
Abstract: This paper examines the controversy over the relative energy efficiencies of R•l34a and R•l2, from a theoretical thermodynamic perspective.In this regard, we have used an in•house process flowsheeting program which allows us to simulate the complete thermodynamic cycle, and investigate the effects of superheat: and subcooling.Spedal attention is given to the suitable basis for comparing the energy efficiencies of different refrigerants calculated from thermodynamic data.Modelling experiments demonstrate the relative extents to which R•l2 and R•l34a respond differently CD superheat and subcooling.With appre>priate superheat and subcooling taken into ce>nsideration, such as applied in standard practice in the home appliance industry, R•l34a can provide COP values essentially equivalent to that of R•12.
Institution: Purdue University West Lafayette
Language: English
Subfield: Mechanical Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: green