Year: 2012
Type: article
Abstract: We report on the design, performance and commissioning of a cryogenic distillation column for low radioactivity underground argon purification that has been constructed at Fermi National Accelerator Laboratory. The plant accepts a mixture of argon, helium, and nitrogen with low argon concentration and is designed to return pure argon with a nitrogen contamination less than 10 ppm. During the commissioning, the distillation column in a continuous mode produced argon 99.9% pure. After running in batch mode, the argon purity was increased to 99.95%, with 500 ppm of nitrogen remaining. The argon production rate was about 1 kg/day.
Institution: Fermi National Accelerator Laboratory
Language: English
Subfield: Aerospace Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W1587754355