Simplified modeling for infiltration and radon entry
Year: 1992
Type: article
Abstract: Air leakage in the envelope.s of residential buildings is the primary mechanism for provided ventilation to those buildings.For radon the same mechanisms that drive the ventilation, drive the radon entry This paper attempts to provide a simplified physical model that can be used to understand the interactions between the building leakage distribution, the forces that drive infiltration and ventilation, and indoor radon concentrations, Combining both ventilation and entry modeling together allows an estimation of Radon concentration and exposure to be made and demonstrates how changes in the envelope or ventilation system would affect it.This paper will develop simplified modeling approaches for estimating both ventilation rate and radon entry rate based on the' air tightness of the envelope and the driving forces.These approaches will use conventional leakage values (i.e.effective leakage area) to quantify the air tightness and include natural and mechanical driving forces.This paper will introduce a•simplified parameter, the Radon Leakage Area, that quantifies the resistance to radon entry.To be practical for dwellings, modeling of the occupant exposures to indoor pollutants must be simple to use• and not require unreasonable input data.This paper presents the derivation of the simplified physical model, and applies that model to representative situations to explore the tendencies to be expected under different circumstances.
Author: Max H. Sherman
Language: English
Subfield: Radiation
Field: Physics and Astronomy
Domain: Physical Sciences
Open Access status: green
Funder: U.S. Department of Energy
OpenAlex ID: W159788243