Abstract: Many cryogenic heat exchangers employ high-conductance metallic screens or perforated plates separated by insulating spacers normal to the fluid flow direction. The former insures a high rate of heat transfer between the fluid streams while the latter reduces longitudinal conduction. Packed-bed regenerators employing wire screens, perforated plates, or granular particles also have a similar structure. In these exchangers, any individual plate or particle has very high thermal conductivity and is essentially at a single temperature. As a result, the temperature profile along the length consists of many steps, rather than a single continuous curve. Conventional analysis based on a continuous temperature profile tends to overestimate the efficiency of these exchangers. Axial conduction down the bed, caused by finite contact or spacer resistance, further reduces the effectiveness. The ineffectiveness due to axial conduction adds to that due to finite number of plates and finite heat transfer coefficient. A closed form expression is derived for the efficiency of a compact heat exchanger with given design N/sub tu/ where the exchanger consists of layers of metallic screens, plates, or particle layers. It is observed that the effect of discrete temperature profile becomes significant when the per stage design N/sub tu/ exceeds about 0.5.
Authors: Sunil Sarangi, John Barclay
Language: English
Subfield: Mechanical Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W1597934063