A Capillary Tube-Refrigerant Charge Design Methodology for Household Refrigerators-Part II: Equivalent Diameter and Test Procedure
Year: 2012
Type: conference-paper
Abstract: In the first part of this work an experimental apparatus was designed and constructed to map the energy consumption of a household refrigerator subjected to several combinations of refrigerant charge and expansion restriction. In the second part, the expansion restriction imposed by the pair metering valve-capillary tube was converted into an equivalent tube diameter applying two different procedures: dry nitrogen flow and mathematical modeling. An empirical correlation to estimate the energy consumption based on the capillary tube inner diameter and refrigerant charge was also developed and used during the minimization process. Different strategies were also explored in order to reduce the amount of experiments to a minimum. It was found that at least 14 data points, collected with three different refrigerant charges, are required to ensure the convergence of the energy consumption minimization process.
Authors: Joel Boeng, C. Melo
Language: English
Subfield: Mechanical Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: green
Awards: G1288759684, G2932195667
OpenAlex ID: W160347156