The Development of an Aptamer-based Surface Plasmon Resonance (SPR) Sensor for the Real-time Detection of Glycated Protein
Year: 2012
Type: article
Abstract: The direct detection of blood proteins can benefit anumber of scientific and clinical applications, one of which is
glycated protein monitoring for diabetes diagnosis and treatment.
The formation of glycated proteins is proportional to the average
glucose concentration over a certain past time period. Thus, the
protein glycation level can reflect the long-term glycemic
compliance according to a specific protein’s half-life. Albumin has
a short half-life of 2-3 weeks and the glycated albumin (GA) level
could indicate the average plasma glucose concentration on a
monthly basis, which provides valuable complementary information
for more complete assessment of glycemic control in comparison to
conventional glucose and HbA1c testing. (HbA1c is a common
long-term glucose indicator with a half-life of 7-8
weeks).According to a literature review, no glycated protein
monitor, other than HbA1c, is currently on the commercial market
for diabetes guidance. A cost-effective, real-time monitoring
approach to assess the HbA1c and other proteins (such as GA) could
bring significant advantages for diabetes diagnosis and treatment,
whereas the existing monitoring technology does not make this
economical.In this research project, the feasibility of using an
aptamer-based surface plasmon resonance (SPR) sensors for the
real-time detection of glycated blood proteins (i.e., GA) has been
studied. For the purpose of establishment, the well documented
thrombin binding aptamers were immobilized onto a gold sensing
surface using a two-step amine coupling method. The experimental
results show that the aptamer functionalized SPR is a well suited
sensing platform for selective blood protein detection
applications. To obtain the specific receptors that enable
selective detection, the human serum albumin (HSA) binding aptamer
has then been developed using the magnetic beads-based Systematic
Evolution of Ligands by EXponential amplification process
(MB-SELEX). The experimental protocol of the in vitro selection
process have been standardized. The developed aptamers have shown a
common pattern in sequence and a similarity in secondary
structures. Furthermore, the glycated albumin (GA) binding aptamers
have been identified and the sensor performance has been
characterized under different binding conditions. The aptamer
functionalized sensor has shown a better performance in both
sensitivity and selectivity for the detection of GA compared to the
well documented phenylboronate monolayer-based sensor, indicating
that aptamers are a better receptor choice for GA detection
applications.Finally, a novel multi-channel aptamer
functionalization sensor and a feedback data processing model have
been developed based on the glycated and non-glycated albumin
binding aptamers. The experimental results demonstrate that the
aptamer-based SPR sensor has the ability to detect GA levels within
a 25 % error range.This dissertation provides the essential
foundation experiments to demonstrate the feasibility of using
aptamer-based SPR sensor for the detection of glycated…
Author: Rui Zheng
Institution: University of Toledo
Language: English
Subfield: Molecular Biology
Domain: Life Sciences
Open Access status: green
OpenAlex ID: W1616574312
