Abstract: This study compares the use of traditional rectal thermometry with an implantable microchip temperature transponder in cats. The microchip transponder was implanted over the shoulder blades and was programmed with cat identification information. Concurrently, the cats were involved in a study in which they were infected experimentally with feline herpesvirus 1; this situation enabled temperature comparisons in both normal and abnormal ranges. Results from the microchip transponder technique were compared with rectal thermometry by using a concordance test of agreement. These data revealed close agreement between rectal and microchip transponder thermometry in the cat at both normal and abnormal temperature ranges.