Abstract: A high-voltage probe has been designed and constructed; it is unique because it may be used for both high-voltage dc and for transient measurements. The probe is rated at 100-kV dc with a short transient rating of 150-kV peak. System risetime is less than 2 ns. The input impedance is 1000 M..cap omega.. shunted by 13 pF. A distributed RC network providing the desired attenuation is housed in a 25.4-cm-dia cylindrical housing. A 15.2-m length of coaxial cable connects the probe to a termination network at the oscilloscope input. The oscilloscope input impedance must be at least 100 k..cap omega.. to maintain the correct dc attenuation ratio.