Water hammer due to the sudden stopping of a flashing flow
Year: 1991
Type: conference-paper
Abstract: Measurements of the peak pressure occurring when a valve at the end of a pipe passing a flashing flow is slammed shut have been made. Scatter is considerable. The pressure trace indicates that condensing of the vapor occurs at essentially constant pressure after which a single phase liquid water hammer occurs. A simplified hand calculation and a more elaborate computer calculation are both shown to bound the data. For designing pipe supports, the peak pressure can be conservatively estimated assuming the flow is pure liquid. Before the spike is experienced, however, a delay, while the pipe is being filled, ensues. What constitutes a rapid valve closure in this problem, compared to single phase liquid rapid valve closure, is quite different. To avoid the waterhammer, a much slower stroking of the valve is needed.
Authors: Sweeney, E.J., Griffith, P.
Institution: Massachusetts Institute of Technology
Language: English
Subfield: Civil and Structural Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W1663736141
