Abstract: Effective utilization of daylight is one of several design strategies that promise to provide substantial energy savings for commercial buildings. Despite the revived interest in the field, there are very few occupied buildings for which performance data verify the magnitude and cause of real savings. In order to optimize costs it is first necessary to understand building performance data in sufficient detail to assess the contradictory component impacts. This can be done most effectively using an hour-by-hour energy analysis model, in this case DOE-2.1B. This paper reports conclusions of an extensive series of computer analyses in two climates to determine the energy use and demand impacts of fenestration in commercial buildings. Particular attention is paid to the tradeoffs involved in using fenestration to daylight perimeter zones. The study includes the effects of climate, orientation, window area, U-value, shading coefficient, visible transmittance, lighting power density, and lighting control strategy.
Authors: Stephen Selkowitz, R. Burke Johnson, R. Sullivan, Sunkyu Choi
Language: English
Subfield: Building and Construction
Field: Engineering
Domain: Physical Sciences
Open Access status: green
Funder: U.S. Department of Energy
Awards: G1643223109, G193590374