Work

Systematic timing errors in laser-based transit-time velocimetry

Year: 2013
Type: conference-paper
Abstract: Laser diagnostics for measuring velocity or acceleration are based either on transit-time or Doppler effect. Transit-time techniques rely on the displacement of tracers during a given amount of time. Tracers can be either particles (Particle Image Velocimetry, Particle Tracking Velocimetry) or molecules (Molecular Tagging Velocimetry). In these diagnostics, the velocity or acceleration is controlled by the timing of lasers that are used in dual, triple, or quadruple pulse mode. Of all the sources of uncertainties associated with these techniques, timing has been considered negligible except for occasional misfires or very high-speed flows (? 10 km/s). However, in Q-switched lasers, such as Nd:YAG or Nd:YLF, a systematic bias was measured between the triggered pulse separation (?t) and actual pulse separation values. Several different lasers from various manufacturers were characterized and it was found that the timing uncertainty has a complex relation to the laser power, frequency, and in some cases the triggered ?t. When such lasers are used in a dual cavity configuration, errors vary up to 0.5 ?s and up to 1 ?s for single cavity lasers with dual pulse capabilities. Such large discrepancy can lead to very significant systematic errors in measurements. The various reasons for these discrepancies are discussed and several different approaches are proposed to measure and correct this source of uncertainty.
Language: English
Open Access status: green
OpenAlex ID: W174848157
FWCI: 4.261
Cites: 9
Cited by: 15
Related to: 10