The first x-ray diffraction peak of water as a function of temperature in the range 4 – 63 °C
Year: 2013
Type: conference-paper
Abstract: X-ray diffraction structure functions for water flowing in a 1.5 mm diameter siphon in the temperature range 4 – 63 °C were obtained using a 20 keV beam at the Australian Synchrotron. These functions were compared with structure functions obtained at the Advanced Light Source for a 0.5 mm thick sample of water in the temperature range 1 – 77 °C irradiated with an 11 keV beam. The two sets of structure functions are similar, but there are subtle differences in the shape and relative position of the two functions suggesting a possible differences between the structure of bulk and siphon water. In addition, the first structural peak (Q0) for water in a siphon, showed evidence of a step-wise increase in Q0 with increasing temperature rather than a smoothly varying increase. More experiments are required to investigate this apparent difference.
Authors: Stephen Hughes, John C. Barry
Language: English
Subfield: Materials Chemistry
Field: Materials Science
Domain: Physical Sciences
Keywords: liquid water, temperature dependence, bulk water
Open Access status: green
OpenAlex ID: W175140268