Computational method for realistic estimates of the dose to active marrow
Year: 1984
Type: article
Abstract: Calculation of absorbed dose to active marrow from photon radiation is a complex problem because electronic equilibrium may not exist in the vicinity of soft tissue-bone mineral interfaces. Snyder et al. recognized the intractable geometry of trabecular bone in their studies of photon transport in the body and formulated marrow dose estimates in a conservative manner. Other investigators have noted that this approach leads to overestimate by factors of 3 or more at low photon energy. In this paper the absorbed dose is formulated in terms of physical and anatomical parameters defining the energy deposition in the marrow space. 17 references, 2 figures, 1 table.
Authors: Keith F. Eckerman, M. Cristy
Language: English
Topic: Radiation Dose and Imaging
Subfield: Radiology, Nuclear Medicine and Imaging
Field: Medicine
Domain: Health Sciences
Open Access status: green
Funder: U.S. Department of Energy
Awards: G1702950523, G88967483