Work

Pretreatment of Methane Fermentation Effluent by Physico-chemical Processes before applied to Soil Trench System

Year: 2006
Type: article
Abstract: In this study, ammonia stripping and magnesium ammonium phosphate hexahydrate OH6POMgNH 244 ⋅ method (MAP) were evaluated for pretreating methane fermentation effluent before applied to soil trench system. For ammonia stripping, the optimal calcium hydroxide dosage was searched systematically. The results shown that the overdosing of calcium hydroxide, 27.5/l wastewater, achieved not only higher ammonia but higher phosphorus, COD, SS and Turbidity removal efficiency. In addition, the volume and settling rate of precipitation was also relative optimal. As expected, ammonia stripping performance was highly dependent on air/water ratio; however, from the point of view of engineering application, air flow rate as 5 l/min for 1 l wastewater should be optimal. For MAP, the optimal pH was about 9 based on NNH 4 −+, PPO34 − − and COD removal efficiency. Although NNH 4 −+ and PPO34 − − removal reached almost maximum at −++ 3442 PO:NH:Mg mole ratio 1:1:1, additional +2Mg dosage, such 1.5:1:1, is preferred for thoroughly PPO34 −− removal. In conclusion, compared with MAP precipitation, ammonia stripping is much more suitable for pretreating methane fermentation effluent in engineering application.
Authors: X. Lei, S. Shimada, K. Intabon, Xiaohui Lei, Satoru Shimada, Keo Intabon, Takaaki Maekawa, X. Lei, S. Shimada, K. Intabon
Language: English
Open Access status: green
OpenAlex ID: W1772807152
FWCI: 2.056
Cites: 14
Cited by: 8
Related to: 10