Work

Ultra-wide Range Gamma Detector System for Search and Locate Operations

Year: 2005
Type: article
Abstract: Collecting debris samples following a nuclear event requires that operations be conducted from a considerable stand-off distance. An ultra-wide range gamma detector system has been constructed to accomplish both long range radiation search and close range hot sample collection functions. Constructed and tested on a REMOTEC Andros platform, the system has demonstrated reliable operation over six orders of magnitude of gamma dose from 100's of uR/hr to over 100 R/hr. Functional elements include a remotely controlled variable collimator assembly, a NaI(Tl)/photomultiplier tube detector, a proprietary digital radiation instrument, a coaxially mounted video camera, a digital compass, and both local and remote control computers with a user interface designed for long range operations. Long range sensitivity and target location, as well as close range sample selection performance are presented.
Language: English
Subfield: Radiation
Open Access status: green
OpenAlex ID: W186925313
FWCI: 0.309
Cites:
Cited by: 1
Related to: 10