Work

Nursing sensitive process and outcome measures in patients with adult respiratory distress syndrome (ARDS) receiving mechanical ventilation

Year: 2004
Type: dissertation
Abstract: Acute Respiratory Distress Syndrome, or ARDS causes a rapid and severe \ndeterioration in pulmonary function resulting in respiratory failure, and requires \nmechanical ventilation in a critical care setting. The current evidenced-based approach to \nthe intermittent manipulation of ventilator settings is known as the “lung protective \nphilosophy” and incorporates lower lung volumes and pressures than have historically \nbeen used. The nursing contribution to the process of mechanical ventilation involves \nmonitoring both the patient and the ventilator to identify responses to therapy and initiate \nfurther intervention as indicated. The contribution of this monitoring activity to patient \noutcomes in ARDS care has not been adequately quantified. \nIn this study, monitoring intensity, therapeutic intervention intensity, compliance \nwith lung protective parameters, and adverse events were explored as potential nursing \nsensitive indicators using a retrospective, descriptive study design. The sample consisted \nof 67 ARDS patients (45 men and 22 women) between the ages of 18 and 79 having \nreceived mechanical ventilation. Study variables were measured during the first 72 hours \nof treatment following diagnosis with ARDS based on nursing documentation in the \nmedical record. Compliance with lung protective parameters for peak alveolar pressure \nand tidal volume were found to be lower than in previous clinical trials. The high \nprevalence of subjects (n=29) with risk factors for abdominal compartment hypertension \nin the sample was thought to contribute to this finding. The exclusion of these subjects \nwith such risk factors did not result in significant increase in compliance with these \nparameters. \nMonitoring intensity was positively correlated with both severity of illness \n(r=0.500) and therapeutic intervention intensity (r=0.313), and was inversely related to \ncompliance with lung protective parameters (r=0.392). The model including monitoring \nintensity, severity of illness, and compliance with lung protective parameters did not \nadequately fit the data (p= 0.082), and explained little of the variation in compliance with \nlung protective parameters. Only two adverse events (self-extubation and medication \nerror) were reported during the study period. \nThe heterogeneity of the ARDS population, the process of integrating research \ninto practice, the interdependent nature of the interventions of interest, and retrospective \nnature of the study were identified as issues that affected the sensitivity of the selected \nstudy variables to the unique contribution of nursing to the care of patients with ARDS \nreceiving mechanical ventilation in this study. Further exploration of the sensitivity of \nthese variables to the unique contribution of nursing, as well as the identification of other \nnursing sensitive variables is needed.
Author: Terry Jones
Language: English
Field: Medicine
Open Access status: green
OpenAlex ID: W1881009459
Cites: 253
Cited by:
Related to: 10