Durability of adhesive joints between concrete and FRP reinforcement in aggressive environments
Year: 2004
Type: dissertation
Abstract: The durability of the bondline between concrete and its fiber-reinforced \npolymer reinforcement was characterized at various temperature and humidity \nlevels. The bondline consisted of an epoxy primer, an epoxy putty and an \nepoxy saturant. In principle, fracture could occur anywhere in this bondline, but \nattention was focused on the concrete/primer interface in this study because \npreliminary experiments indicated that this was the dominant failure mechanism. \nThe initial part of the constitutive modeling of the epoxy primer was \nconducted using linear viscoelastic experiments. Confined compression \nexperiments determined two linear material functions simultaneously. Because \nthis was a relatively new experiment, the results were validated by conducting \nbulk compliance experiments. The viscoelastic region of the bulk modulus was \nas wide as that of the tensile and shear relaxation moduli. This result \ncontradicts previous conceptions but is agreement with some other recent \nobservations. Thermal and hygral expansions were also measured and used in a \nhybrid nonlinear viscoelastic constitutive model. \nThe hybrid model captured the hygrothermal nonlinear viscoelastic \ndeformation of the epoxy primer. This model is a combination of Schapery’s \nmodel and Popelar’s shear modified free volume model. Torsion tests were \nconducted and used to calibrate the distortional parameters in the free volume \nmodel. Tension experiments were performed at four different temperature and \nhumidity levels and were used to calibrate the dilatational, thermal and hygral \nparameters in the hybrid model. The linear and hygrothermal nonlinear \nviscoelastic constitutive models were used in the analysis of time-dependent \ninterfacial fracture between concrete and epoxy primer. \nA generalized time-dependent J integral was used as a fracture parameter for \ncharacterizing the time-dependent interfacial fracture. This was used instead of \nthe strain energy release rate and the stress intensity factor because of the \nnonlinear viscoelastic deformation of the primer. Schapery’s pseudo stress \nmodel was calibrated using tension data at various temperature and humidity \nlevels because it is required for the generalized J integral. An instrumented \nwedge test was conducted in order to determine the interfacial fracture energy at \nseveral loading rates and various temperature and humidity levels. The crack \nlength was measured as a function of wedge speeds during steady state crack \ngrowth. The generalized J integral and cohesive zone size or failure zone size \nwere computed using finite element analyses that incorporated the pseudo stress \nmodel. The pseudo stress model, cohesive zone size and the generalized J \nintegral were all used to compute the work input into the failure zone, which \nwas then equated to the fracture energy. The loading rate, temperature and \nhumidity level all affected the fracture energy, which decreased with increasing \ntemperature and humidity levels.
Author: Soojae Park
Institution: The University of Texas at Austin
Language: English
Subfield: Building and Construction
Field: Engineering
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W1902226882