Work

Severe Accident Testing of a Personnel Airlock

Year: 2016
Type: article
Abstract: Sandia National Laboratories (Sandia) is investigating the leakage potential of mechanical penetrations as part of a research program on containment integrity under severe accident loads for the US Nuclear Regulatory Commission (NRC). Barnes et al. (1984) and Shackelford et al. (1985) identified leakage from personnel airlocks as an important failure mode of containments subject to severe accident loads. However, these studies were based on relatively simple analysis methods. The complex structural interaction between the door, gasket, and bulkhead in personnel airlocks makes analytical evaluation of leakage difficult. In order to provide data to validate methods for evaluating the leakage potential, a full-size personnel airlock was subject to simulated severe accident loads consisting of pressure and temperature up to 300 psig and 800/degree/F. The test was conducted at Chicago Bridge and Iron under contract to Sandia. Julien and Peters (1989) provide a detailed report on the test program. 6 refs., 5 figs.
Language: English
Open Access status: green
OpenAlex ID: W190877837
FWCI:
Cites: 1
Cited by:
Related to: 10