Work

Thermal Performance Testing of Long Evaporative Section Thermosyphons Used in Solar Water Heating System

Year: 2015
Type: article
Abstract: In this study, the aim is to i nvestigate the application of ethanol & acetone flui d thermosyphons as a heat transfer tool in a solar water heater (SWH).For this purpose, a long evaporati ve section thermosyphons (LES T) are designed, constructed and tested at temperatures of 50˚C,60˚C&70˚C heat source(Hot Water).In this work the LES T are made of copper tube of 1000 mm length of internal diameter 24.4 mm and 1 mm thickness.The working flui d employed are ethanol & acetone with filling rati o (FR) 40% .The lengths of evaporator, adi abatic & condenser sections are 600mm, 200mm and 200 mm respecti vely.Maxi mum heat transfer capaci ty of each LEST is 500W.The LES T placed centrally in 2 i nch UPVC pi pe.The 2 inch UPVC pi pe water jackets are provi ded in both evaporati ve & condenser section of prescribed length for hot water circulation.Heat source at 50˚C,60˚C,70˚C&80˚C temperature of hot water taken during experi mentation.Two Immersion water heaters of 3.5 KW were used for water heating process.The Inclination of the LES T varies between 0˚ to 90˚.Seven different tests were carried out in different orientation angle.The results show that efficiency of thermosyphons mode are in range of 50 % to 71% .Experi mentall y found that the vertical position is the best performance of thermosyphons for maxi mum mass flow rate of flui d.It was also found that there is no more di fferences in thermal performance of thermosyphons at an angle of 45˚, 60˚ & 90˚ as compare wi th vertical position (90˚).The overall thermal resis tance also calculated in the range of 0.069˚C/W to 0.127 ˚C/W.Experi mentally found that overall thermal resistance decrease from horizontal position to vertical position.Less overall thermal resistance causes better performance of thermosyphons.After comparison between two thermosyphon (acetone and ethanol flui d) performance i t was found that long evaporati ve section acetone fl ui d thermosyphon can be used in solar water heating system, because it will gives better performance in l ow temperature range .
Authors: Harendra Kumar Jha, Mahesh.G. Bhong
Language: English
Open Access status: green
OpenAlex ID: W1911711898
FWCI: 0.275
Cites: 2
Cited by: 1
Related to: 9