Work

Simultaneous Measurement of External Refractive Index and Temperature by Using a Side-polished Fiber Bragg Grating with a Polymer Overlay

Year: 2010
Type: article
Abstract: 498.8 nm/RIU, 694.9 nm/RIU, 1312 nm/RIU로 측정되었다. A hybrid grating sensing device based on a side-polished fiber Bragg grating (FBG) with a polymer overlay is proposed for simultaneous measurement of external refractive index and temperature. The side-polished FBG, which is insensitive to ambient index change, is utilized for detecting temperature variation, and the polymer overlay is coated on the side-polished FBG for measurement of ambient index change. The temperature sensitivities of the side-polished FBG and the polymer overlay were measured to be 0.01 nm/$^{\circ}C$ and -0.58 nm/$^{\circ}C$, respectively, in a temperature range from $30^{\circ}C$ to $100^{\circ}C$. The ambient index sensitivities of the polymer overlay were measured to be 498.8 nm/RIU in an ambient index range from 1.33 to 1.39, 694.9 nm/RIU from 1.39 to 1.42, and 1312 nm/RIU from 1.42 to 1.44.
Language: Korean
Open Access status: bronze
OpenAlex ID: W2022753539
FWCI:
Cites: 11
Cited by:
Related to: 9