Diagnosis of Power and Control Cables Using Change of Reflection Coefficients Due to Weak Fault
Year: 2014
Type: article
Abstract: Since power and control cables have narrow bandwidth due to their loss at high frequencies, it is difficult to detect the weak fault using conventional reflectometry. It is because the reflected wave caused by the weak fault is overlapped and hidden by the ripple of the strong reflected wave from the end of the cable. This paper proves that the reflected wave from the weak fault can be considered to be linearly superposed on the strong reflected wave from the end of the cable based on the transmission line theory. Then, the weak fault point is experimentally diagnosed using the difference between reflection coefficients before and after the fault generation.
Institutions: Sungkyunkwan University, Ajou University
Language: English
Subfield: Electrical and Electronic Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: diamond
OpenAlex ID: W2061966582