Abstract: Major improvements have been made on the Adam injector at the SuperHILAC heavy ion accelerator. Adam is a pressurized Cockcroft-Walton injector, typically run at voltages in excess of 2 MeV. The PIG ion source was redesigned to increase the length of the discharge column and the extraction slit, while remaining within the magnet poles of the source magnet. To maintain cooling, part of the thinner soft-iron end cap was replaced with a copper section, modifying the magnetic circuit. These modifications resulted in more than doubling the ion beam intensity. A large liquid nitrogen cryotrap within the pressure vessel was replaced by an RF shielded, commercial cryopump head with a custom pumping array. This reduced the pressure at the ground end of the injector by an order of magnitude and reduced that at the source by a factor of two, even with the additional gas load due to the longer slit. The pressure reduction was essential to minimize charge exchange loss of the highly charged ions, such as Fe{sup 4+}. Plans are underway to replace a 3 watt cryopump in the terminal end with a 10 watt pump which is expected to result in a 50% faster cooldown time, and greater than a 50% increase in running time before regeneration of the cryopump is necessary. 3 refs., 4 figs.