Work

Some factors affecting bacterial colony counts in urinary infection.

Year: 1967
Type: article
Study design: Observational Study
Abstract: then be taken to cross-match blood, empty the uterus, give further oxytocics, and repair genital trauma.The report by the Ministry of Health (1963) on maternal deaths in England and Wales for the years 1958-60 emphasized the frequency with which attendants failed to realize the serious state of patients who had bled.Considerable underestimation of the cxtent of blood loss often contributed to this failure.Of the 742 deaths studied 130 were believed to have haemorrhage as the primary factor leading to death.In 61 of these (31 with avoidable factors) the bleeding was postpartum.This investigation has shown that in routine hospital prac- Zice there is considerable underestimation of blood loss, and yet this hospital is representative of those with a high standard of antenatal and intranatal care.The present finding of virtually invariable underestimation, especially when the recorded loss exceeds 300 ml., suggests most strongly that unappreciated and underestimated blood loss is a much more important factor in many maternal deaths than available statistics show.Reports have appeared in which the criterion for assessing the effect of anaesthetic and oxytocic preparations on the third stage of labour has been the incidence of postpartum haemor- rhage (Embrey et al., 1963 ; Friedman, 1957 ; McBride, 1954).The findings in this survey suggest that this criterion is of little value unless clinical estimation of blood loss is replaced by accurate measurement.It is hoped that the present investigation will emphasize to those attending vaginal deliveries how often considerable haemorrhages occur, so that by early action disastrous exsanguinations will be avoided. SummaryA method of accurately measuring blood loss is outlined.Blood is extracted in a washing-machine and measured spectro- metrically as oxyhaemoglobin.The bleeding that occurred after 57 vaginal deliveries was measured.When this measured amount was compared with the estimate recorded at the time of delivery the estimate was reasonably correct for small losses.However, when the recorded loss exceeded 300 ml.underestimation was invariable, anJ as the loss became greater so did the amount of undercstimation.On the basis of these measurements it is calculated that in over 20%/ of vaginal deliveries the blood loss exceeds 500 ml.A systolic blood pressure below 100 mmn.Hg and a pulse rate above 100 beats per minute are late signs of depleted blood volume and indicate commencing failure of the compensatory mechanisms.I wish to thank Mr. H.G. Dixon and Mr. W. G.
Source: BMJ
Authors: A. P. Roberts, R. E. Robinson, R. W. Beard
Language: English
Subfield: Urology
Field: Medicine
Open Access status: bronze
OpenAlex ID: W1967379498
FWCI: 24.17
Cites: 19
Cited by: 89
Related to: 10