Interobserver reproducibility of fully quantitative pixel-wise analysis of clinical CMR perfusion imaging

Year: 2014
Type: article
Study design: Observational Study
Abstract: Quantitative first pass cardiac magnetic resonance (CMR) perfusion imaging has shown excellent interobserver agreement at a sector level in healthy volunteers and patients. In this study, we compare the myocardial blood flow (MBF) estimates in sector-wise and pixel-wise analysis. We also study the interobserver variability in pixel-wise MBF estimates from patients with coronary artery disease (CAD). First pass CMR imaging was performed on 29 patients with known or suspected CAD (15 females, age 54.9 ± 14.3 years). Twenty of the patients, defined as the normal group, had minimal or no stenosis ( < 30% by computed tomographic angiogram) and nine patients, defined as the CAD group, had significant CAD ( > 70% stenosis by invasive coronary angiography). All patients were scanned on a 1.5T scanner using a steady state free precession imaging sequence for regadenoson stress perfusion followed by rest perfusion 20 minutes later. Two observers independently traced the myocardial regions of interest in the mid-ventricular slice and quantified the MBF in sector-wise and pixel-wise analyses by a model-constrained deconvolution approach. Pixel-wise MBF estimates were averaged to six transmural sectors to compare with sector-wise analysis. Pearson correlation, Bland-Altman analysis, and paired student t-test were used to compare the results. There was excellent correlation between pixel-wise vs. sector-wise MBF quantification for the 20 normal and nine CAD patients (Figure 1 ). In both patient groups, Bland-Altman analysis showed no significant bias between the two methods of quantification (mean bias from 0.01 to 0.12 ml/min/g). Limits of agreement were good (2SD range from 0.26 to 0.98 ml/min/g, p = NS for all comparison). Interobserver agreement of pixel-wise MBF was excellent for both normal and CAD groups (Figure 2 ). The interobserver agreement was good (2SD range from 0.38 to 0.96 ml/min/g, p = NS for all comparisons) with no significant interobserver bias (mean bias from 0.02 to 0.15 ml/min/g). The stress MBF in the ischemic zone of patients with > 70% stenosis was 1.72 ± 0.75 ml/min/g by pixel-wise analysis which was significantly lower than remote MBF (2.85 ± 0.74 ml/min/g, p < 0.001). Excellent correlation between pixel-wise vs. sector-wise MBF quantification . Excellent agreement of pixel-wise MBF quantification between two independent observers . Clinical first pass CMR perfusion can be quantified at the pixel level and the results agree well with sector-wise comparison. There is an excellent interobserver agreement in pixel-wise quantification of patients with CAD.
Language: English
Field: Medicine
Open Access status: gold
Estimated APC paid: $3,000
OpenAlex ID: W1967681610
FWCI:
Cites:
Cited by:
Related to: 10