Abstract: We describe depth-resolved microscopy of cortical hemodynamics with high-speed spectral/Fourier domain optical coherence tomography (OCT). Stimulus-evoked changes in blood vessel diameter, flow, and total hemoglobin were measured in the rat somatosensory cortex. The results show OCT measurements of hemodynamic changes during functional activation and represent an important step toward understanding functional hyperemia at the microscopic level.
Source: Optics Letters
DOI: 10.1364/ol.34.003086
Language: English
Subfield: Biomedical Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: bronze
Awards: G1169916466, G1523888516, G1553028739, G1637721069, G182365684, G2213582121, G2529054258, Remodeling and recovery in the neurovascular unit, G41276363, G593967775, Optical Biopsy Using Optical Coherence Tomography, Multiscale Dynamic Measurements and Modeling of Cerebrovascular Physiology, G9000081091, G9000083564, G9000095117