Robust indexing for automatic data collection

Year: 2004
Type: article
Abstract: Improved methods for indexing diffraction patterns from macromolecular crystals are presented. The novel procedures include a more robust way to verify the position of the incident X-ray beam on the detector, an algorithm to verify that the deduced lattice basis is consistent with the observations, and an alternative approach to identify the metric symmetry of the lattice. These methods help to correct failures commonly experienced during indexing, and increase the overall success rate of the process. Rapid indexing, without the need for visual inspection, will play an important role as beamlines at synchrotron sources prepare for high-throughput automation.
Language: English
Open Access status: hybrid
Estimated APC paid: $5,110
OpenAlex ID: W1971536893
FWCI: 1.774
Cites: 25
Cited by: 162
Related to: 10