Lightweight wrist photoplethysmography for heavy exercise: motion robust heart rate monitoring algorithm
Year: 2015
Type: article
Abstract: The challenge of heart rate monitoring based on wrist photoplethysmography (PPG) during heavy exercise is addressed. PPG is susceptible to motion artefacts, which have to be mitigated for accurate heart rate estimation. Motion artefacts are particularly apparent for wrist devices, for example, a smart watch, because of the high mobility of the arms. Proposed is a low complexity highly accurate heart rate estimation method for continuous heart rate monitoring using wrist PPG. The proposed method achieved 2.57% mean absolute error in a test data set where subjects ran for a maximum speed of 17 km/h.
Source: Healthcare Technology Letters
Authors: Po‐Hsiang Lai, Insoo Kim
Language: English
Subfield: Biomedical Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: hybrid
Estimated APC paid: $2,500
Funder: Samsung
OpenAlex ID: W1983397055